Search

Pocan BF4212 000000

  _More Info 
  _Data sheet ISO (PDF) 

 

Data sheet

PBT, 15% glass fibers, injection molding, flame retardant
 
ISO Shortname:  ISO 7792-PBT,GF15,GFHMR,09-070; ISO 1043-4 FR(17)
PropertyTest ConditionUnitStandardguide value1
Rheological properties
CMelt volume-flow rate260 °C; 2.16 kgcm³/(10 min)ISO 1133-114
CMolding shrinkage, parallel60x60x2; 260 °C / MT 80 °C; 600 bar%ISO 294-40.7
CMolding shrinkage, transverse60x60x2; 260 °C / MT 80 °C; 600 bar%ISO 294-41.1
Post- shrinkage, parallel60x60x2; 120 °C; 4 h%ISO 294-40.1
Post- shrinkage, transverse60x60x2; 120 °C; 4 h%ISO 294-40.1

Mechanical properties (23 °C/50 % r. h.)
CTensile modulus1 mm/minMPaISO 527-1,-27000
CTensile Stress at break5 mm/minMPaISO 527-1,-2110
CTensile Strain at break5 mm/min%ISO 527-1,-22.6
Izod impact strength23 °CkJ/m²ISO 180-1U25
Izod impact strength-30 °CkJ/m²ISO 180-1U25
Izod notched impact strength23 °CkJ/m²ISO 180-1A<10
Izod notched impact strength-30 °CkJ/m²ISO 180-1A<10
Flexural modulus2 mm/minMPaISO 178-A6200
Flexural strength2 mm/minMPaISO 178-A160
Flexural strain at flexural strength2 mm/min%ISO 178-A3.4

Thermal properties
CMelting temperature10 °C/min°CISO 11357-1,-3222
CTemperature of deflection under load1.80 MPa°CISO 75-1,-2190
Burning behavior UL 940.75 mmClassUL 94V0
Burning behavior UL 941.5 mmClassUL 94V0
Burning behavior UL 943.0 mmClassUL 94V0
Resistance to heat (ball pressure test)°CIEC 60695-10-2212
Glow wire test (GWFI)0.75 mm°CIEC 60695-2-12960
Glow wire test (GWFI)1.5 mm°CIEC 60695-2-12960
Glow wire test (GWFI)3.0 mm°CIEC 60695-2-12960
Glow wire test (GWIT)0.75 mm°CIEC 60695-2-13850
Glow wire test (GWIT)1.5 mm°CIEC 60695-2-13750
Glow wire test (GWIT)3.0 mm°CIEC 60695-2-13725
CVicat softening temperature50 N; 50 °C/h°CISO 306212

Electrical properties (23 °C/50 % r. h.)
CVolume resistivityOhm·mIEC 62631-3>1E14
CSurface resistivityOhmIEC 62631-3>1E17
CElectric strength1 mmkV/mmIEC 60243-129
Comparative tracking index CTISolution APLCUL 746A3

Other properties (23 °C)
CWater absorption (Saturation value)Water at 23 °C%ISO 620.4
CWater absorption (Equilibrium value)23 °C; 50 % RH%ISO 620.2
CDensitykg/m³ISO 11831533

Processing conditions for test specimens
CInjection molding-Melt temperature°CISO 294250
CInjection molding-Mold temperature°CISO 29480

Processing recommendations
Drying temperature dry air dryer°C -120
Drying time dry air dryerh -4-8
Melt temperature (Tmin - Tmax)°C -240-260
Mold temperature°C -80-100

Notes
1Typical properties: these are not to be construed as specifications
CThese property characteristics are taken from the CAMPUS plastics data bank and are based on the international catalogue of basic data for plastics according to ISO 10350.
Disclaimer
Disclaimer for developmental products (don't use)
This is a Sales Product at the developmental stage (a Trial Product). For this reason, no assurances can be given as to type conformity, processability, long-term performance characteristics or other production or application parameters. No definitive statements can be made regarding the behavior of the product during processing or use. The purchaser/user uses the product entirely at his own risk. The marketing and continued supply of this material are not assured and may be discontinued at any time. Our products are sold in accordance with the current version of our General Conditions of Sale and Delivery.
Test values
Unless specified to the contrary, the values given have been established on standardized test specimens at room temperature. The figures should be regarded as guide values only and not as binding minimum values. Kindly note that, under certain conditions, the properties can be affected to a considerable extent by the design of the mould/die, the processing conditions and the coloring.
Processing note
Under the recommended processing conditions small quantities of decomposition product may be given off during processing. To preclude any risk to the health and well-being of the machine operatives, tolerance limits for the work environment must be ensured by the provision of efficient exhaust ventilation and fresh air at the workplace in accordance with the Safety Data Sheet. In order to prevent the partial decomposition of the polymer and the generation of volatile decomposition products, the prescribed processing temperatures should not be substantially exceeded. Since excessively high temperatures are generally the result of operator error or defects in the heating system, special care and controls are essential in these areas.
LANXESS Performance Materials GmbH | DE 50569 COLOGNE | Germany
Date: 07.06.2023